563YS Load Cell , 250kg.10,000kg/ 1,000 lb.20,000 lb; Special features: High accuracy regulations up to 5 000d for scales; class III; Stainless steel, welded seal construction, protection to IP68; Harsh environment or food industry; Hazardous area approved to Ex ib II CT4; Available Options: Service temperature range up to 120OC [248OF]; Available with metric thread and UNC thread; 6-wire circuit
The data for deviation of linearity, repeatability, hysteresis error and temperature effect on sensitivity are typical values. The sum of these data meets the requirements according to OIML R60.
More Products, please visit www.pneumatic-products.com, Or email to us: hanlixia@pneumatic-products.com
| Technical Data |
|
| Type |
563YS |
|
Accuracy class according to OIML R60 Maximal numbers of load cell verification intervals ( n L C ) |
|
C3 3 000 / 5 000 |
|
Maximal capacity (Emax) |
lb/kg |
1,000;1,500;2,500; 4,000;SE-5,000/ 250;500;1,000;2,000 |
5,000;10,000/ 3,000;5,000 |
15,000; 20,000/ 10,000 |
|
Weight (G), approx. |
kg |
1 |
1.8 |
4.1 |
|
Minimumload cell verification interval(Vmin) Sensitivity (Cn) Zero balance Temperature effect on sensitivity (TKc) * Temperature effect on zero balance (TKo) Non-linearity (dlin) * Repeatability (drep) * Hysteresis error (dhy) * Creep (dDR)in 30 min. Input resistance (RLC) [Red(+)-black(-)] Output resistance (RO) [Green(+)-white(-)] Reference excitation voltage (Uref) Maximal excitation voltage nsulation resistance (Ris) Nominal temperature range Service temperature range Storage temperature range |
% of Cn mV/V mV/V % of Cn/k % of Cn/k % % % % O O V(DC/AC) V(DC/AC) GO oC [ o F] oC [ o F] oC [ o F] |
0.02 2±0.25% ±0.06 < ±0.0012 < ±0.0040 < ±0.023 < ±0.023 < ±0.023 < ±0.030 350 ±7 352±3 0.5.10 15 >2[50 VDC ] -10.+40[15.+105] -18.+65[0.+150] -50.+85[-60.+185] |
|
Safe load limit (EL) Breaking load (Ed) |
% of Cn % of Cn |
150 300 |
|
Protection class (IP) acc. to IEC529 |
|
IP68 |
|
Material |
|
Stainless Steel 17-4PH |
|
Optionally |
|
Explosion proof version(Ex ib II CT4) | |